Specifications – VRV AURORATM Series 208-230 & 460V Heat Recovery Units
2017 PF-AUR-230 09-17
Specicaons are subect to change at any me. United Refrigeraon is not responsible for changes, errors & omissions.
56
Model
208-230V/3Ph/60Hz RELQ72TATJU RELQ96TATJU RELQ120TATJU RELQ144TATJU RELQ192TATJU RELQ240TATJU
460V/3Ph/60Hz RELQ72TAYDU RELQ96TAYDU RELQ120TAYDU RELQ144TAYDU RELQ192TAYDU RELQ240TAYDU
Combination 2 x RELQ72T 2 x RELQ96T 2 x RELQ120T
Performance
Nominal Cooling Capacity Btu/h 72,000 96,000 120,000 144,000 192,000 240,000
Nominal Heating Capacity Btu/h 81,000 108,000 135,000 162,000 216,000 270,000
Operation Range Cooling °F (°C) DB 231 to 122 (-51 to 50)
Operation Range Heating °F (°C) WB -22 to 60 (-30 to 16)
Sound Pressure dBA 60 61 63.5 63 64 67
Fan
Airflow (Cooling) CFM 6956 7989 8806 6956 + 6956 7989 + 7989 8806 + 8806
Airflow (Heating) CFM 7283 7283 7283 7283 + 7283 7283 + 7283 7283 + 7283
Fan Motor Output and Quantity kW 0.80 x 2 0.80 x 2 0.80 x 2 0.80 x 2 + 0.80 x 2 0.80 x 2 + 0.80 x 2 0.80 x 2 + 0.80 x 2
Fan ESP. Standard/Max in. WG 0.12/0.32
Compressor
Compressor Type Type Inverter
Capacity Control % 11~100 10~100 9~100 6~100 5~100 4~100
Refrigerant
Piping
Liquid Pipe (Main Line) in 3/8 3/8 1/2 1/2 5/8 5/8
Suction Gas Pipe (Main Line) in 3/4 7/8 1-1/8 1-1/8 1-1/8 1-3/8
Discharge Gas Pipe (Main Line) in 5/8 3/4 3/4 7/8 1-1/8 1-1/8
Refrigerant
Piping
Layout
Maximum Vertical Pipe Length OD Above ft 164 (295 With Field Settings)
Maximum Vertical Pipe Length OD Below ft 131 (195 With Field Settings)
Max. Vertical Pipe Length between IDU ft 98
Maximum Actual Pipe Length ft 541
Maximum Equivalent Pipe Length ft 623
Total Piping Length ft 1640
Refrigerant Refrigerant R410A
Connection
Ratio
Connectable Indoor Unit Ratio % 70 - 2002
Maximum Number of Indoor Units Qty 12 16 20 25 33 41
Unit
Outdoor Unit Size (HxWxD) in (mm) 66-11/16 x 48-7/8 x 30-3/16 (1694 x 1242 x 767) 66-11/16 x 48-7/8 x 30-3/16 + 66-11/16 x 48-7/8 x 30-3/16
(1694 x 1242 x 767) + (1694 x 1242 x 769)
Weight lbs.(kgs) 727 (330) 793 (360) 793 (360) 727+727 (330+330) 793+793 (360+360) 793+793 (360+360)
Electrical
(RELQ-TATJU)
Maximum Over Current Protection (MOP) A 70 80 90 70 + 70 80 + 80 90 + 90
Minimum Circuit Amps (MCA) A 60.8 76.5 83.4 60.8 + 60.8 76.5 + 76.5 83.4 + 83.4
Electrical
(RELQ-TAYDU)
Maximum Over Current Protection (MOP) A 35 45 50 35 + 35 45 + 45 50 + 50
Minimum Circuit Amps (MCA) A 28.1 39.8 43.4 28.1 + 28.1 39.8 + 39.8 43.4 + 43.4
>> Compressor technology with new spiral
design and injection valves for precise
refrigerant control
>> Strong and efficient motors for optimized
compressor performance and part load
efficiencies
ADDITIONAL INFORMATION
Before purchasing this appliance, read important
information about its estimated annual energy
consumption, yearly operating cost, or energy
efficiency rating that is available from your
retailer. Visit www.daikincomfort.com for
details.
1 Cooling operation can be extended down to -4ºF with application rules and conditions
2 Varies based on indoor model selected
COMMERCIAL VRV H/R AURORA