an eye on the oil level in the reservoir. With the cylinder fully extended, the oil level should not
hydraulic oil.
-
voir.
BATTERY CABLES
Low voltage will cause the motor to run at higher amps and may cause damage to other electrical
components. To minimize voltage drop, increase the gauge size of the battery cables as the
length of the positive and ground cables increase.
Cable Length Wire Gauge Nominal OD (in)
1 to 2 feet 4 gauge 0.43
3 to 4 feet 2 gauge 0.49
5 to 7 feet 1 gauge 0.56
8 to 9 feet 1/0 gauge 0.61
10 to 12 feet 2/0 gauge 0.66
13 to 15 feet 3/0 gauge 0.72
16 to 19 feet 4/0 gauge 0.78
Diagram A-4 Diagram A-5